Skip to Content
Search
Your Cart
Loading...
Categories
Loading...
Home Search 0 Wishlist
Category

Special armatures

IV/00094/14
Connecting strip as per drawing stainless steel 1.4301
KB15NC-533708
2/2-way coaxial valve, G 3/8" 0-250 bar, 115VAC, DN 3, NC, direct-acting Body: 1.4104/steel nickel-plated, Medium: air incl. terminal box and special voltage oil- and grease-free
KB15NC-545150
2/2-way coaxial valve, G 3/8" 0-30 bar, 24VDC, DN 8, NC, direct-acting Body: 1.4101/steel nickel-plated Medium: nitrogen -196°C, oil- and grease-free incl. terminal box and reinforcing rings
LP-SG07-50-UWC1253-03
Control valve Type SG07, DN50; PN10/40; NO; Material: Zinc plated steel; Fixed disc 1.4571 Coated; Sliding disc Carbon material; Kvs-value 28 (63%); Characteristic Linear; Valve without actuator; Without Positioner
PSCS-USB
Software including data cable
PS-SEC11-12
Set of packing For Microvalve SEC11
R0S012
Connection tube For sliding gate valves DN80, Incl. Fittings
SK-RV30-15-15-15/25
Seal kit for RV30-15-15-15/25
CVT3-20-XX-XXX
3/2-way-coaxial valve; Directly operated; G3/4"; 0...16bar; 24VDC; DN20; NC; Body: Brass; Medium: Emulsion; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. mounting bracket; Incl. 2 inductive NAMUR limit switches OPEN/CLOSED (B.); Incl. inspection certificate 3.1; With manual operation; TÜV design; ATEX Areas 1, 21: II 2 G Ex mb e II T4 / II 2 D Ex tD A21 IP65 T130 °C And II 2G Ex h IIC T4 Gb / II 2D Ex h IIIC T130°C Db
ATEX Areas 2, 22: II 3G Ex ec IIC T3 Ta -20...+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20...+80°C Dc And II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc ; Special version
CVT3-25-XX-XXX
3/2-way-coaxial valve; Directly operated; G1"; 0...16bar; 24VDC; DN25; NC; Body: Brass; Medium: Emulsion; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. mounting bracket; Incl. 2 inductive NAMUR limit switches OPEN/CLOSED (B.); Incl. inspection certificate 3.1; With manual operation; TÜV design; ATEX Areas 1, 21: II 2 G Ex mb e II T4 / II 2 D Ex tD A21 IP65 T130 °C And II 2G Ex h IIC T4 Gb / II 2D Ex h IIIC T130°C Db
ATEX Areas 2, 22: II 3G Ex ec IIC T3 Ta -20...+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20...+80°C Dc And II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc ; Special version
CVT-32-XX-XXX
2/2-way coaxial valve; Directly operated; G11/4"; 0...16bar; 24VDC; DN32; NC; Body: Brass; Medium: Emulsion; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. mounting bracket; Incl. 2 inductive NAMUR limit switches OPEN/CLOSED (B.); Incl. inspection certificate 3.1; With manual operation; ATEX Areas 1, 21: II 2 G Ex mb e II T4 / II 2 D Ex tD A21 IP65 T130 °C And II 2G Ex h IIC T4 Gb / II 2D Ex h IIIC T130°C Db
ATEX Areas 2, 22: II 3G Ex ec IIC T3 Ta -20...+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20...+80°C Dc And II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc ; Special version
CVT3-32-XX-XXX
3/2-way-coaxial valve; Directly operated; G11/4"; 0...16bar; 24VDC; DN32; NC; Body: Brass; Medium: Emulsion; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. mounting bracket; Incl. 2 inductive NAMUR limit switches OPEN/CLOSED (B.); Incl. inspection certificate 3.1; With manual operation; ATEX Areas 1, 21: II 2 G Ex mb e II T4 / II 2 D Ex tD A21 IP65 T130 °C And II 2G Ex h IIC T4 Gb / II 2D Ex h IIIC T130°C Db
ATEX Areas 2, 22: II 3G Ex ec IIC T3 Ta -20...+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20...+80°C Dc And II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc ; Special version
CVT3-40-XX-XXX
3/2-way-coaxial valve; Directly operated; G11/2"; 0...16bar; 24VDC; DN40; NC; Body: Brass; Medium: Emulsion; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. mounting bracket; Incl. 2 inductive NAMUR limit switches OPEN/CLOSED (B.); Incl. inspection certificate 3.1; With manual operation; ATEX Areas 1, 21: II 2 G Ex mb e II T4 / II 2 D Ex tD A21 IP65 T130 °C And II 2G Ex h IIC T4 Gb / II 2D Ex h IIIC T130°C Db
ATEX Areas 2, 22: II 3G Ex ec IIC T3 Ta -20...+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20...+80°C Dc And II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc ; Special version
CVT3-50-XX-XXX
3/2-way-coaxial valve; Directly operated; G2"; 0...16bar; 24VDC; DN50; NC; Body: Brass; Medium: Emulsion; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. mounting bracket; Incl. 2 inductive NAMUR limit switches OPEN/CLOSED (B.); Incl. inspection certificate 3.1; With manual operation; ATEX Areas 1, 21: II 2 G Ex mb e II T4 / II 2 D Ex tD A21 IP65 T130 °C And II 2G Ex h IIC T4 Gb / II 2D Ex h IIIC T130°C Db
ATEX Areas 2, 22: II 3G Ex ec IIC T3 Ta -20...+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20...+80°C Dc And II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc ; Special version
CVT-40-XX-XXX
2/2-way coaxial valve; Directly operated; G11/2"; 0...16bar; 24VDC; DN40; NC; Body: Brass; Medium: Emulsion; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. mounting bracket; Incl. 2 inductive NAMUR limit switches OPEN/CLOSED (B.); Incl. inspection certificate 3.1; With manual operation; ATEX Areas 1, 21: II 2 G Ex mb e II T4 / II 2 D Ex tD A21 IP65 T130 °C And II 2G Ex h IIC T4 Gb / II 2D Ex h IIIC T130°C Db
ATEX Areas 2, 22: II 3G Ex ec IIC T3 Ta -20...+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20...+80°C Dc And II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc ; Special version
CVT-50-XX-XXX
2/2-way coaxial valve; Directly operated; G2"; 0...16bar; 24VDC; DN50; NC; Body: Brass; Medium: Emulsion; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. mounting bracket; Incl. 2 inductive NAMUR limit switches OPEN/CLOSED (B.); Incl. inspection certificate 3.1; With manual operation; ATEX Areas 1, 21: II 2 G Ex mb e II T4 / II 2 D Ex tD A21 IP65 T130 °C And II 2G Ex h IIC T4 Gb / II 2D Ex h IIIC T130°C Db
ATEX Areas 2, 22: II 3G Ex ec IIC T3 Ta -20...+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20...+80°C Dc And II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc ; Special version
CVF-65-XX-XXX
2/2-way coaxial valve; Directly operated; Flange DN65; PN16; 0...16bar; 24VDC; NC; Body: Stainless steel; Medium: Water; Incl. LED; Special seals; Back pressure tight; Bi-directional flow; Incl. 2 inductive limit switches OPEN/CLOSED (B.); Incl. inspection certificate 3.1;
ATEX Areas 2, 22: II 3G Ex ec IIC T3 Ta -20...+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20...+80°C Dc And II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc ; Special version